klaute
|
3f04957bd3
|
Sample data added - the hardware seemes to be working now.
|
2016-09-24 20:46:35 +02:00 |
|
klaute
|
7e9c8b086e
|
firmware: Analog read was to shaky, the number of read per millisecond is now increased to 20. meas.py: Some modifications to get the output more userfriendly. CSV output is implemented now.
|
2016-09-21 20:02:58 +02:00 |
|
klaute
|
8bc17c45c7
|
Fixed the initial ADC read value problem - the values are to shaking around.
|
2016-09-21 18:27:41 +02:00 |
|
klaute
|
753d91457a
|
Floating point operation fixed - previous calculation result type was integer.
|
2016-09-21 18:07:56 +02:00 |
|
klaute
|
7afaea4745
|
Calculation error fixed and debug output added.
|
2016-09-21 16:22:23 +02:00 |
|
klaute
|
330e4d08a1
|
Some calculation imprevements done.
|
2016-09-21 10:32:10 +02:00 |
|
klaute
|
5038269c24
|
Little code improvements done.
|
2016-09-21 10:00:23 +02:00 |
|
klaute
|
8a56cbb111
|
Plot view added.
|
2016-09-20 20:23:55 +02:00 |
|
klaute
|
9fa0cb2a47
|
Author info header added.
|
2016-09-20 19:49:58 +02:00 |
|
klaute
|
ba41ad0027
|
The meas python script works well now. The get configuration call is disabled now.
|
2016-09-20 19:41:41 +02:00 |
|
klaute
|
a0f06d4fb7
|
New info message added to the firmware. The python script was modified to print out more detaild messages of its activity.
|
2016-09-20 18:51:20 +02:00 |
|
klaute
|
a6dc38f81a
|
Baudrate set to 115200 again, the serial flush call has fixed the serial sending problem.
|
2016-09-20 13:08:56 +02:00 |
|
klaute
|
744a746b7f
|
New serial test tool added - serial connection test.
|
2016-09-20 12:57:28 +02:00 |
|
klaute
|
5149646717
|
Baudrate increased to 115200. Added a python script to manage the SWR meter hard- and firmware behaviour.
|
2016-09-19 22:38:37 +02:00 |
|