#ifndef __CONFIG_H__
|
|
#define __CONFIG_H__
|
|
|
|
// config general setting and behavior of the weatherstation
|
|
|
|
#define WIFI_AUTOCONNECT_TIMEOUT_S 120
|
|
#define WIFI_CONFIG_PORTAL_TIMEOUT_S 120
|
|
#define UPDATE_SENSOR_INTERVAL_S 300
|
|
#define UPDATE_WEBSERVER_INTVERVAL_S 1 // Do not change, bigger values will prevent using webupdater webinterface
|
|
#define DELAY_LOOP_MS 50
|
|
#define POWERSAVING_SLEEP_S 600
|
|
#define EMERGENCY_SLEEP_S 172800 // Sleep for 2 days to recover
|
|
#define RESET_ESP_TIME_INTERVAL_MS (60*60*3*1000) // (60*60*6*1000) // reset every 3 hours
|
|
#define WIND_SENSOR_MEAS_TIME_S 15
|
|
#define INITIAL_WEBSERVER_TIME 20
|
|
|
|
#define ENERGY_SAVING_ITERATIONS 30
|
|
#define WIFI_MINIMUM_SIGNAL_QUALITY 10 // percent
|
|
|
|
#define BAT_LOW_VOLTAGE 3.6
|
|
#define BAT_EMERGENCY_DEEPSLEEP_VOLTAGE 3.5
|
|
|
|
#define SEALEVELPRESSURE_HPA (1013.25)
|
|
|
|
#define STATUS_LED_PIN LED_BUILTIN
|
|
#define ANEMOMETER_PIN D7
|
|
|
|
#ifndef BAT_PINS_D34
|
|
#define BAT_CHARGED_PIN D6
|
|
#define BAT_CHARGING_PIN D5
|
|
#else
|
|
#define BAT_CHARGED_PIN D3
|
|
#define BAT_CHARGING_PIN D4
|
|
#endif
|
|
|
|
#define BME_SCK 13
|
|
#define BME_MISO 12
|
|
#define BME_MOSI 11
|
|
#define BME_CS 10
|
|
#define BME_ADDRESS 0x76
|
|
|
|
#define WEB_UPDATER_HTTP_PORT 8080
|
|
|
|
#endif
|