weatherstation/firmware/config.h
2022-05-16 14:27:39 +02:00

60 lines
1.8 KiB
C

#ifndef __CONFIG_H__
#define __CONFIG_H__
#define SENSOR_TEMPERATURE 0
#define SENSOR_HUMIDITY 1
#define SENSOR_LIGHT 2
#define SENSOR_WINDSPEED 3
#define SENSOR_PRESSURE 4
#define SENSOR_BAT_VOLTAGE 5
#define SENSOR_ESAVEMODE 6
#define SENSOR_BATCHARGESTATE 7
#define BAT_CHARGE_STATE_CHARGED 2.0
#define BAT_CHARGE_STATE_CHARGING 1.0
#define BAT_CHARGE_STATE_NOTCHARGING 0.0
#define ENERGY_SAVE_MODE_ENABLED 1.0
#define ENERGY_SAVE_MODE_DISABLED 0.0
#define WIFI_AUTOCONNECT_TIMEOUT_S 120
#define WIFI_CONFIG_PORTAL_TIMEOUT_S 120
#define UPDATE_SENSOR_INTERVAL_S 300
#define UPDATE_WEBSERVER_INTVERVAL_S 1 // Do not change, bigger values will prevent using webupdater webinterface
#define DELAY_LOOP_MS 50
#define POWERSAVING_SLEEP_S 600
#define EMERGENCY_SLEEP_S 172800 // Sleep for 2 days to recover
#define ENERGY_SAVING_ITERATIONS 30
#define WIFI_MINIMUM_SIGNAL_QUALITY 10 // percent
#define RESET_ESP_TIME_INTERVAL_MS 3600000
#define ROTOR_LENGTH_KM 0.000115
#define WIND_SENSOR_MEAS_TIME_S 5.0
#define SEC_TO_HOUR_FACTOR (60.0 * 60.0)
#define COUNT_TO_KMH ((TWO_PI * ROTOR_LENGTH_KM / WIND_SENSOR_MEAS_TIME_S) * SEC_TO_HOUR_FACTOR)
#define BAT_LOW_VOLTAGE 3.6
#define BAT_EMERGENCY_DEEPSLEEP_VOLTAGE 3.5
#define SEALEVELPRESSURE_HPA (1013.25)
#define STATUS_LED_PIN LED_BUILTIN
#define ANEMOMETER_PIN D7
#ifndef BAT_PINS_D34
#define BAT_CHARGED_PIN D6
#define BAT_CHARGING_PIN D5
#else
#define BAT_CHARGED_PIN D3
#define BAT_CHARGING_PIN D4
#endif
#define BME_SCK 13
#define BME_MISO 12
#define BME_MOSI 11
#define BME_CS 10
#define BME_ADDRESS 0x76
#define INITIAL_WEBSERVER_TIME 20
#define WEB_UPDATER_HTTP_PORT 8080
#endif