Optically improved the readme
This commit is contained in:
parent
880f41e049
commit
3e96da19b6
1 changed files with 40 additions and 36 deletions
76
README.md
76
README.md
|
@ -1,4 +1,4 @@
|
||||||
## Webserver API
|
## Webserver
|
||||||
|
|
||||||
The web server is implemented on the ESP32 and provides various endpoints for operation and display of information. Here are the defined URLs and their functions:
|
The web server is implemented on the ESP32 and provides various endpoints for operation and display of information. Here are the defined URLs and their functions:
|
||||||
|
|
||||||
|
@ -32,7 +32,7 @@ This is an example of a JSON object containing various measurement values and co
|
||||||
"ina226Status": 3,
|
"ina226Status": 3,
|
||||||
"ina226ShuntValue": 0.0002,
|
"ina226ShuntValue": 0.0002,
|
||||||
"ina226AlertFlag": 0,
|
"ina226AlertFlag": 0,
|
||||||
"ina226AlertLimit": 0.1,
|
"ina226AlertLimit": 0,
|
||||||
"ina226CurrentLSB": 0.0005
|
"ina226CurrentLSB": 0.0005
|
||||||
}
|
}
|
||||||
```
|
```
|
||||||
|
@ -52,6 +52,44 @@ This is an example of a JSON object containing various measurement values and co
|
||||||
- `ina226AlertLimit`: The limit value for alerts from the INA226 chip.
|
- `ina226AlertLimit`: The limit value for alerts from the INA226 chip.
|
||||||
- `ina226CurrentLSB`: The value of the least significant bit (LSB) for the current according to the INA226 chip in amperes.
|
- `ina226CurrentLSB`: The value of the least significant bit (LSB) for the current according to the INA226 chip in amperes.
|
||||||
|
|
||||||
|
### Error codes in `errorCode`
|
||||||
|
|
||||||
|
The variable `globalError` is used as a bitmask, where each bit represents a specific error condition. Here are the possible error codes and their meanings:
|
||||||
|
#### Error Codes
|
||||||
|
|
||||||
|
| Descriptive Name | Value | Meaning |
|
||||||
|
|:----------------------------|---------:|:---------------------------------------------------------|
|
||||||
|
| `ERROR_NONE` | 0b00000000 | No error. The device is functioning properly, there are no errors present. |
|
||||||
|
| `ERROR_MAX_CURRENT_EXCEEDED`| 0b00000001 | The maximum current consumption has been exceeded. There might be an overload condition on the device. |
|
||||||
|
| `ERROR_CURRENT_BELOW_MIN` | 0b00000010 | The current consumption is below the permissible minimum. There may be an issue with the power supply. |
|
||||||
|
| `ERROR_MAX_TEMP_EXCEEDED` | 0b00000100 | The maximum temperature has been exceeded. The device could overheat. |
|
||||||
|
| `ERROR_TEMP_BELOW_MIN` | 0b00001000 | The temperature is below the permissible minimum. There is a risk of hypothermia or other temperature-related issues. |
|
||||||
|
| `ERROR_MAX_HUMI_EXCEEDED` | 0b00010000 | The maximum humidity has been exceeded. This could lead to moisture-related problems. |
|
||||||
|
| `ERROR_HUMI_BELOW_MIN` | 0b00100000 | The humidity is below the permissible minimum. There is a risk of low humidity. |
|
||||||
|
|
||||||
|
Please note that multiple errors can occur simultaneously as the bitmasks can be combined. For example, `ERROR_MAX_TEMP_EXCEEDED | ERROR_MAX_HUMI_EXCEEDED` could indicate that both the maximum temperature and humidity have been exceeded.
|
||||||
|
|
||||||
|
#### Error codes ina226Status
|
||||||
|
|
||||||
|
| descriptive name error | value | meaning |
|
||||||
|
|:------------------------------|---------:|:----------|
|
||||||
|
| INA226_ERR_NONE | 0x0000 | OK
|
||||||
|
| INA226_ERR_SHUNTVOLTAGE_HIGH | 0x8000 | maxCurrent \* shunt > 80 mV
|
||||||
|
| INA226_ERR_MAXCURRENT_LOW | 0x8001 | maxCurrent < 0.001
|
||||||
|
| INA226_ERR_SHUNT_LOW | 0x8002 | shunt < 0.001
|
||||||
|
| INA226_ERR_NORMALIZE_FAILED | 0x8003 | not possible to normalize.
|
||||||
|
|
||||||
|
#### Error codes ina226AlertLimit
|
||||||
|
|
||||||
|
| description alert register | value | a.k.a. |
|
||||||
|
|:---------------------------|-------:| -------:|
|
||||||
|
| INA226_SHUNT_OVER_VOLTAGE | 0x8000 | SOL |
|
||||||
|
| INA226_SHUNT_UNDER_VOLTAGE | 0x4000 | SUL |
|
||||||
|
| INA226_BUS_OVER_VOLTAGE | 0x2000 | BOL |
|
||||||
|
| INA226_BUS_UNDER_VOLTAGE | 0x1000 | BUL |
|
||||||
|
| INA226_POWER_OVER_LIMIT | 0x0800 | POL |
|
||||||
|
| INA226_CONVERSION_READY | 0x0400 | |
|
||||||
|
|
||||||
3. **`/config`**
|
3. **`/config`**
|
||||||
- **Output:** HTML page for configuration.
|
- **Output:** HTML page for configuration.
|
||||||
- **Return:** Webpage with form fields for configuring parameters.
|
- **Return:** Webpage with form fields for configuring parameters.
|
||||||
|
@ -120,40 +158,6 @@ This is an example of a JSON object containing various measurement values and co
|
||||||
|
|
||||||
These URL paths form a basic API for interacting with the ESP32 device, allowing users to display real-time data, configure settings, initiate demo modes, and update the firmware.
|
These URL paths form a basic API for interacting with the ESP32 device, allowing users to display real-time data, configure settings, initiate demo modes, and update the firmware.
|
||||||
|
|
||||||
### Error codes in `errorCode`
|
|
||||||
|
|
||||||
The variable `globalError` is used as a bitmask, where each bit represents a specific error condition. Here are the possible error codes and their meanings:
|
|
||||||
|
|
||||||
#### `ERROR_NONE` (0b0000000000000000)
|
|
||||||
|
|
||||||
No error. The device is functioning properly, there are no errors present.
|
|
||||||
|
|
||||||
#### `ERROR_MAX_CURRENT_EXCEEDED` (0b0000000000000001)
|
|
||||||
|
|
||||||
The maximum current consumption has been exceeded. There might be an overload condition on the device.
|
|
||||||
|
|
||||||
#### `ERROR_CURRENT_BELOW_MIN` (0b0000000000000010)
|
|
||||||
|
|
||||||
The current consumption is below the permissible minimum. There may be an issue with the power supply.
|
|
||||||
|
|
||||||
#### `ERROR_MAX_TEMP_EXCEEDED` (0b0000000000000100)
|
|
||||||
|
|
||||||
The maximum temperature has been exceeded. The device could overheat.
|
|
||||||
|
|
||||||
#### `ERROR_TEMP_BELOW_MIN` (0b0000000000001000)
|
|
||||||
|
|
||||||
The temperature is below the permissible minimum. There is a risk of hypothermia or other temperature-related issues.
|
|
||||||
|
|
||||||
#### `ERROR_MAX_HUMI_EXCEEDED` (0b0000000000010000)
|
|
||||||
|
|
||||||
The maximum humidity has been exceeded. This could lead to moisture-related problems.
|
|
||||||
|
|
||||||
#### `ERROR_HUMI_BELOW_MIN` (0b0000000000100000)
|
|
||||||
|
|
||||||
The humidity is below the permissible minimum. There is a risk of low humidity.
|
|
||||||
|
|
||||||
Please note that multiple errors can occur simultaneously as the bitmasks can be combined. For example, `ERROR_MAX_TEMP_EXCEEDED | ERROR_MAX_HUMI_EXCEEDED` could indicate that both the maximum temperature and humidity have been exceeded.
|
|
||||||
|
|
||||||
## Functions
|
## Functions
|
||||||
|
|
||||||
### configureIna226()
|
### configureIna226()
|
||||||
|
|
Loading…
Reference in a new issue